100M Ethernet lightning protection control signal lightning protection network surge protection.
Brief introduction
The control signal network lightning protection dual one protector uses high quality low capacitance gas discharge tube, TVS and other devices. It has advantages of small insertion loss, fast response speed, accurate clamping, low output pressure and so on. It is used to protect all kinds of voltage connected control signals and network signal equipment sensitive to electromagnetic interference and protect sensitive control signal lines. The road is not damaged by lightning overvoltage, induced overvoltage, over current and electrostatic discharge.
Product features
1. multi-functional overvoltage protection, lightning and overpressure are no longer afraid of disasters.
2. the speed of response is 0.001 seconds, and the voltage is controlled in the range that the equipment can withstand.
3. low output residual pressure to further ensure safety
4. transmission performance, excellent insertion loss, high transmission frequency and low attenuation coefficient, ensure that the lightning arrester does not affect the system performance.
Product specification
Type | TRSS-RJ45 |
Max continuous operating voltage Uc(VAC) | 5V |
Nominal discharge current (8/20μS) ln(kA) | 5kA |
Voltage protection level Up(kV)≤ | 20V |
Adaptive date transfer rate | 100/1000Mbps |
Insertion loss | ≤1dB |
Respeonse Time | ≤1ns |
Protect network lines | 1~8 |
Surface Properties | 100x25x25 |
Line interface | RJ45 |
Way to lnstall | Series Connection |
Working principle of product
The signal surge protector is connected to the front end of the protected equipment. When the transmission line is impacted by the inductive thunder and other transient overvoltage, the impact current is discharged to the earth through the protection branch of the surge protector, and the output voltage is placed in the allowable voltage range of the equipment, thus ensuring the safety of the operating equipment.
Use of attention
1. when installing, attention should be paid to cables coming in and out of surge protective devices, so as to avoid the two coupling of surge.
2. the protected equipment must have good grounding, and the grounding impedance is in accordance with the relevant national standards.
3. After correct installation, it can work steadily for a long time. If it is found that the transmission performance of the system is reduced or the signal is interrupted due to the cause of surge protection, it should be maintained or replaced in time.
4. please recognize the interface and connection mode.
Product packaging:Carton packing
Transportation method
1. Express company: FEDEX,UPS,DHL,TNT